Model |
RTY-MS |
Working volume |
500L-2000L |
Filling volume |
65-80% |
Material |
Wetted parts are SS316L, and others is SS304. |
Surface finish |
inside surface is 0.28-0.6μm by mechanical polishing, ( passivation or electro-polish are optional ) |
outside surface is 0.4-0.8μm by satin finish. |
Pressure |
Working pressure inside vessel:0.2mpa |
Design pressure inside vessel: 0.25mpa |
Working pressure inside jacket:0.3mpa |
Design pressure inside jacket: 0.35mpa |
Pressure can be also designed according to client's detail requirement. |
Agitation |
1.Fermentor use SEW decelerator |
2.top mechanical agitator with two layer six blade impeller, one layer defoamer and four baffles. |
3.mechanical seal (single or double mechanical seal) |
4.speed range: 50-400rpm (it depends on the size of the vessel) |
Equips of vessel |
1.using alcohol flame inoculation |
2.sterile sampling vale and bottom valve |
3.PH, DO, temp. sensor on lower side, side glass, top with foam and level probe, and 12v sight glass with lamp, etc. |
Construction |
Floor-type |
One fermentor vessel with one control system (Siemens PLC and HMI) |
Operating panel |
Chinese and English version |
                                                                                        Main components and controls of system |
PH |
1.On-line check and measure, and digitization fully automatic control; |
2.PH, acid and base gang control. Peristaltic pump automatically adjust to feed acid and base; |
3.Control range 2-12pH, measure precision±0.01 pH, control precision±0.1 pH; |
4.It has auto alarm function. |
5.pH sensor and signal transmission line, Mettler toledo |
DO |
1.On-line check and measure, cascade with rpm; digital display. |
2.Range 0-100% or 0-200%, precision ±1%; |
3.It has auto alarm function; |
4.DO sensor and signal transmission line, Mettler toledo |
Foam control |
1.Automatically control and automatically alarm; |
2. Stainless steel electrode check, peristaltic pump automatically add defoamer. |
Feed control |
1. Automatically control and automatically alarm; |
2.Stainless steel electrode check, peristaltic pump automatically feeding |
Temp. control |
1.PID fully digitization signal processing, digitization control settings |
2.Circulating water automatically control temperature |
3.Measure range 0-150 degrees celsius, control range 15-45 degrees celsius,control precision±0.2 degrees celsius |
4.Pt 100Ωtemp. Sensor |
5.system with electrical heater to control the temp inside vessel |
6.water pump circulation |
7.solenoid valve to control |
Rotate speed |
1. Automatically control , with auto alarm function |
2. Siemens frequency converter to adjust the speed. |
Pressure |
1 Manually adjusting with pressure gauge and manual valve (standard system) |
2. Automatically adjusting with pressure transmitter and PID valve and pneumatic valves (optional) |
Air flow |
1.Manually adjusting with rotor meter and manual valve (standard system) |
2.Automatically adjusting with mass-flow meter and pneumatic valves (optional) |
3.Air in filter , tail gas filter , with PALL cartridge, precision 0.2μm |
Sterilization |
1.it can be SIP by connecting with steam |
2.Manually control with manual valve (standard one) |
3.Automatic control with pneumatic valves (optional) |
Control |
Siemens PLC, and Siemens 10.4" LCD touch screen(HMI) and RITAI program |
PC |
1.PC with Kingview software for recording function (optional) |
2.PC with Siemens remote control and Kingview recording function (optional) |
3.printer (optional) |