Model NO.: CY-KJT-2V
HS Code: 8474202000
Model NO.: CY-KJT-2V
HS Code: 8474202000
Laboratory automatic stainless steel pressure control with solenoid valveÂ
Application of pressure control equipmentÂ
KJT-2V is an automatic pressure control kit for keep chamber at constant pressure from 10Kpa to 230 KPa
( 75 Torr to 1750 Torr , or 0.1 atm --- 2 atm )
Specification of pressure control equipment
Equipment includes        |
- One Pressure Transducer with M14 Male Port :   0 - 230 KPa  with 1% accuracy
- Two Solenoid Valves with connecting ports of 1/4'' BSPP
-  ( Male )Â
- One control box with digital pressure Display and controller.  Â
- 110V-220VAC power cable and plug included
- Canon connectors are preinstalled with transducer and solenoid  valve,as well as back of control box.
|
Typical Operation Procedures         Â
|
- Install one solenoid valve to one end of tube flange,  then connect valve to inlet gas tank ( 1/4" I.D rubber hose required)
- Install another  solenoid valve to another end of tube flange,  then connect the valve to vacuum pump
- Install pressure transducer to tube flange
- Plug all connector to control box, and plug control box to  110VAC ( or 220VAC ) power source.
- Set pressure low limit and high limit on digital controller then,  tube furnace will keep pressure with desired range accurately.
|
Application Notes
|
Gas flow-in/out rate can largely affect system pressure control accuracy,Â
the minimum range of pressure control recorded by    Â
using the system shown in below is : Â
-   +/- 100 mtorr (<1 torr),
-   +/- 5 torr (1~760 torr),
|
Warranty |
One year limited with lifetime support |
Laboratory automatic stainless steel pressure control with solenoid valveÂ
Application of pressure control equipmentÂ
KJT-2V is an automatic pressure control kit for keep chamber at constant pressure from 10Kpa to 230 KPa
( 75 Torr to 1750 Torr , or 0.1 atm --- 2 atm )
Specification of pressure control equipment
Equipment includes        |
- One Pressure Transducer with M14 Male Port :   0 - 230 KPa  with 1% accuracy
- Two Solenoid Valves with connecting ports of 1/4'' BSPP
-  ( Male )Â
- One control box with digital pressure Display and controller.  Â
- 110V-220VAC power cable and plug included
- Canon connectors are preinstalled with transducer and solenoid  valve,as well as back of control box.
|
Typical Operation Procedures         Â
|
- Install one solenoid valve to one end of tube flange,  then connect valve to inlet gas tank ( 1/4" I.D rubber hose required)
- Install another  solenoid valve to another end of tube flange,  then connect the valve to vacuum pump
- Install pressure transducer to tube flange
- Plug all connector to control box, and plug control box to  110VAC ( or 220VAC ) power source.
- Set pressure low limit and high limit on digital controller then,  tube furnace will keep pressure with desired range accurately.
|
Application Notes
|
Gas flow-in/out rate can largely affect system pressure control accuracy,Â
the minimum range of pressure control recorded by    Â
using the system shown in below is : Â
-   +/- 100 mtorr (<1 torr),
-   +/- 5 torr (1~760 torr),
|
Warranty |
One year limited with lifetime support |