Technical Parameters |
Working environments |
Temperature: -30'C~+70'C(can be customized to -45'C~+85'C) |
Relatively humidity: 95%(25'C) |
Pressure:Â 86kPa~106kPa |
Power Supply |
Single phase: 220V 50Hz   Three phase:380V 50Hz |
Tolerance: Single phase Voltage(-15%/+10%)  Three phase Voltage(±10%) |
Frequency(±5%), harmonic  content (<5%), Direct Current (±10%) |
Insulation resistance |
1)Resistance between input terminal and case should be more than 20M . |
2)Resistance between input terminal and power supply terminal should be more than 50M . |
3)Resistance between power supply terminal and case should be more than 50M . |
The motor insulation level |
Level F(Level H is selectable) |
Protection level |
IP68(underwater 20M\96hours) |
Anti-explosion level |
EXDÂ IIBT4\EXDÂ IICT4 |
 |
On-Off Type |
Start frequency |
650 times per hour |
Designed lifetime |
Minimum maintenance-free time:30,000 times |
Working form |
Short time working type, rated run time will be 15mins(customized to 30mins) |
 |
Regulated Type |
Start Frequency |
1200 times per hour |
Designed lifetime |
No less than times |
Working form |
Intermittent periodic-type, minimum rated load sustained rate is 25% |
Basic parameters |
Basic error: ≤ ±0.1% |
Hysteresis: ≤ 0.5% |
Dead zone: 0.1%~9.9% continuously adjustable |
Damping characteristic: undamped |
Input and output signal |
Analogue input 4-20mADC, input impedance ≤ 250 ; |
Analogue output4-20mADC, load resistance ≥ 750 ; |
Linear error ≤ 0.5%; |
Supply voltage: 24VDC provided by internal actuator; |
Actuator with a build-in servo amplifier; |
Input and output signal channel take optoelectronic  isolationÂ
|
Passive junction capacity: 250V/5A AC; 30V/5A DC. |